StrobeGuard™ SG-60E


Data Sheet ( PDF )

High Intensity White Strobe Lighting System

FAA Type:
L-856 High Intensity Lighting
ICAO Type: Type A High Intensity Obstacle Light

ETL Certified: FAA Advisory Circular AC
150/5345-43F

Compliant to: Canadian Aviation Regulation
(CAR)621.19, ICAO Annex 14,
MIL-C-7989, DGAC of Mexico

Use:
High intensity obstruction lighting systems are typically used on structures taller than 500' (150M) above ground level to provide aviation safety. The use of a high intensity lighting system typically eliminates the need to paint the structure with aviation red and white stripes. Hughey & Phillips high intensity obstruction lights are designed for lighting tall structures such as television and radio towers, chimneys, cooling towers, tall buildings, catenary river crossings and bridges.

Design:
The StrobeGuard™ High Intensity Lighting System consists of multiple flashheads controlled by a single lighting control. The quantity and location of flashheads used is generally determined by the structure;s height and diameter. The StrobeGuard™ controller constantly monitors the operation of each flashhead, and provides alarm contact closure upon any failure. The control automatically switches between day, twilight, and night intensifies by the use of a calibrated photocell. StrobeGuard™ flashheads incorporate a louver system to minimize ground scatter light, resulting in a "community friendly" lighting system. The StrobeGuard™ system can be combined with a red lighting system for areas where white lighting at night may be undesirable.

Features:
• Fail-safe monitoring system
• Parabolic Optics minimize "ground scatter" light: <3% of peak intensity at -10
• Two-wire cable for sync, mode and monitoring
• Safety interlocks in each flashhead
• Long-life internally triggered strobe tubes
• Automatic three-level intensity control
• Manual intensity override
• Easily accessible replaceable components
• Plug-in-play circuit cards
• Remote alarm contacts
• Stainless steel NEMA 4X enclosure
• Vertical level indicator and adjustment system
• Low power consumption
• Minimal wind loading and weight

StrobeGuard™ Control
StrobeGuard™ controls contain the flash interval and timing circuits, intensity selection controls and monitoring circuitry with status indicators. The StrobGuardTM control system is designed to operate up to 24 flashheads at a distance of up to 2500 feet (760 M), using a noise-resistant communications format. Each control is equipped with the necessary manually operated controls to test all modes of operation. Bi-color green/red LEDs are provided to indicate proper operation of fault of each flashhead.

Flashhead Advantages
Each StrobeGuard™ Flashhead contains a flashtube, reflector assembly, power supply and trigger circuitry in a single enclosure. All circuit boards are plug-in-play, meeting all physical and electrical requirements of MIL-I-40658B including conformal coating for weather resistance. StrobeGuard™ Flashheads are supplied with lighting arrestors capable of withstanding repeated 10,000-amperecurrent surges. The flashheads utilize an internally triggered strobe tube that eliminates ozone, a corrosive agent that can damage wiring and circuitry over time.

Specifications:

Photometric Day
Twilight
Night
Beam Spread
Horizontal Coverage
Cut off Angle
Flash Rate
270,000 candela +- 25% (FAA)
20,000 candela +- 25% (FAA)
2,000 candela +- 25% (FAA)
3% vertical minimum
120o - Min. 3 flasheads per level for 360o coverage
<3% light output at -10o Vertical
40 flashes per minute (FPM)
Environmental Temperature

Humidity
Will withstand exposure to:
-55c to +55c
-67f to 130f
95% relative humidity
Windo-blown rain from any angle
Salt-laden atmosphere
Wind speed of 240kph (150mph)
Mechanical Weight, Controller
Dimensions, Controller

Weight, Flashead
Dimensions, Flashead

Enclosure Rating
Enclosure Material
11kg (24lb)
255mm H x 305mm W x 152mm D
14" H x 12" W x 6" D
37kg (82 lbs)
365mm H x 411mm W x 324 mm D
14.4" H x 16.2" W x 12.75" D
NEMA 4X
304 Stainless Steel
Electrical Input Voltages

Input Frequency
Power Consumption
120, 208, 240, 277, 380, 480V
Single or Three Phase
50 or 60 Hz
0.55kVA per flashead


Flashhead Mounting Details: